Enmet EX-6165 Manual de usuario Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
EX-6120, 6165 SERIES IR
ENMET Corporation
10
6 Sensor Replacement
W
ARNING
:
Power must be removed from the EX-6120,
6165
S
ERIES
IR before this or any internal procedure. Failure
to do so may cause damage to equipment, bodily injury or death.
6.1 Inferred Sensor
Step1
Remove the set screw counter-clockwise.
Step 2
Turn cover securing stud counter-clockwise to allow cover to open.
Set Screw