Enmet EX-5100 Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Enmet EX-5100. ENMET EX-5100 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ENMET Corporation
PO Box 979
Ann Arbor, MI 48106-0979
Manual part number
80003-096
MCN-416, 04/03/09
EX-5100 C
OMBUSTIBLE
Manual
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - EX-5100 C

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 Manual part number 80003-096 MCN-416, 04/03/09 EX-5100 COMBUSTIB

Pagina 2 - List of Figures and Tables

ENMET Corporation EX-5100 COMBUSTIBLE 8 5.0 Maintenance of the EX-5100 CAUTION: Do not open the EX-5100 S/T in a classified area. CAUTION: Do Not

Pagina 3 - 1.0 Introduction

EX-5100 COMBUSTIBLE ENMET Corporation 9 5.2 Calibration of the EX-5100 Calibration is the process of setting the instrument up to read accurately

Pagina 4 - 2.0 Features of the EX-5100

ENMET Corporation EX-5100 COMBUSTIBLE 10 Calibration: Calibration of Standard Gases: Calibration of the EX-5100 should be preformed using the tar

Pagina 5

EX-5100 COMBUSTIBLE ENMET Corporation 11 5.2.1 Zero Adjust A ZERO function should be performed only when the EX-5100 sensor/transmitter is expose

Pagina 6

ENMET Corporation EX-5100 COMBUSTIBLE 12 Normal Display Mode SelectMenu0LEL MENU HOLD the magnet over the MENU switch for 2 – 4 seconds

Pagina 7

EX-5100 COMBUSTIBLE ENMET Corporation 13 5.3 Heater Voltage Settings Heater Voltages are necessary for Catalytic sensors. They are preset at the

Pagina 8 - S/W X.X

ENMET Corporation EX-5100 COMBUSTIBLE 14 6.0 Replacement Part Numbers ENMET replacement part numbers: Description Part Number Sensor, Catalytic

Pagina 9

PO Box 979 680 Fairfield Court Ann Arbor, Michigan 48106-0979 734.761.1270 Fax 734.761.3220 Returning an Instrument for Repair ENMET instrume

Pagina 10

Repair Return Form Mailing Address: ENMET Corporation PO Box 979 Ann Arbor, Michigan 48106 Phone Number: 734.761.1270 FAX Number: 734.

Pagina 11 - Calibration Cover

Table of Contents 1.0 INTRODUCTION ...

Pagina 12

EX-5100 COMBUSTIBLE ENMET Corporation 1 1.0 Introduction The ENMET EX-5100 sensor/transmitters (S/T) is, 3-wire, 24VDC 4-20 ma S/T for the detec

Pagina 13 - Table 4: Calibration Time

ENMET Corporation EX-5100 COMBUSTIBLE 2 2.0 Features of the EX-5100 See Figure 1 for location of features: Feature Description Display LCD: Indi

Pagina 14

EX-5100 COMBUSTIBLE ENMET Corporation 3 3.0 Installation of the EX-5100 CAUTION: Area must be declassified during installation. The ENMET EX-5100

Pagina 15

ENMET Corporation EX-5100 COMBUSTIBLE 4 3.2 Wiring the EX-5100 to a Control Unit CAUTION: Area must be declassified during installation. Run cond

Pagina 16 - 7.0 WARRANTY

EX-5100 COMBUSTIBLE ENMET Corporation 5 EX-5100 Interior Expanded View EX-5100 Interior Assembled View Figure 3: Terminal Positions EX-510

Pagina 17 - 680 Fairfield Court

ENMET Corporation EX-5100 COMBUSTIBLE 6 4.0 Operation of the EX-5100 It is best to have the EX-5100 transmitters powered up and operational for 2

Pagina 18 - Repair Return Form

EX-5100 COMBUSTIBLE ENMET Corporation 7 4.2 Normal Display Mode When the EX-5100 is installed as described in section 3, and in clean air, the PO