Enmet ISA-44-2OD Manual de usuario Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
ENMET Corporation ISA-44-2-OD
10
Relay Hook-up
See Figure 8 for an example of how to use the relay contacts.
Table 5: Relay Function
Relay
Channel function
K1 1 High Alarm
K2 1 Low Alarm
K3 2 Oxygen
K4 3 High Alarm
K5 3 Low Alarm
CAUTION: Actual wiring will not exit the enclosure at the nearest point. The bottom of the enclosure is the best
entrance/exit surface. You must punch holes and use NEMA-4X watertight fittings.
Figure 8: Suggested Relay Hook-Up Configuration
Fan
Relay
110V
AC
Low
110V
AC
Low
110V
AC
High
110V
AC
High
External Lamp
(Amber)
External Lamp
(Red)
External
Horn
Install a separate
switch to silence
an auxiliary alarm
K1
K2
K3K3
K4
K5
TB1
TB2
TB3
TB6
TB4
TB5
Vista de pagina 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 31 32

Comentarios a estos manuales

Sin comentarios